@erfanakbarnia6202
@erfanakbarnia6202 - 28.12.2020 21:44

Thanks to danfoss
If there will set of training for hot gas by pass valves it could be very helpful

Ответить
@TheRealoldcar
@TheRealoldcar - 07.05.2021 00:35

love the quality of your txvs

Ответить
@mugilant8553
@mugilant8553 - 15.05.2021 18:04

Crisp and clear information, 🙏

Ответить
@ryanmalin
@ryanmalin - 01.12.2021 23:40

Counterclockwise decreases superheat? Clockwise increase superheat? Thank you

Ответить
@michaelt.4806
@michaelt.4806 - 23.02.2022 18:42

Every refrigerant system has it's own and specific ideal superheat. The factory 4K is simply playing it safe, Danfoss does not want You to back flush your compressor. What you have to do is to adjust your TXV to the point it starts hunting and back it of 1/4 turn (T2/TE2 other valve look it up) . You do this at end of cycle when your system has reached its working temperature. If every technician would take the time to correctly adjust the superheat we all would safe massive amounts of energy and lots of compressors.

Ответить
@abdullah_q8171
@abdullah_q8171 - 29.07.2022 21:57

This method dosent make evaporate frozen ?

Ответить
@abdullah_q8171
@abdullah_q8171 - 02.08.2022 17:29

If i need more cooler to my package unit how i adjust txv ?

Ответить
@noppadol.pusampaopusampao705
@noppadol.pusampaopusampao705 - 07.10.2022 19:20

TEX5 How to adjust

Ответить
@noppadol.pusampaopusampao705
@noppadol.pusampaopusampao705 - 07.10.2022 19:24

ขอวิธีการปรับเอ็กแปนชั่นวาล์ว รุ่น TEX5 ขอบคุณครับ

Ответить
@xincai951
@xincai951 - 22.12.2023 08:09

How often do you see TXV needs to be adjusted? I have seen a system that’s running 9F sub cool and superheat is 24F. Factory asking for 8-18F superheat. New system too.

Ответить
@swapmanjrekar7613
@swapmanjrekar7613 - 21.02.2024 21:29

Hello, good information there, thank u..

We have an issue in our marine packaged aircon system which has Danfos TEX...

The entire line after TEX till suction of compressor along with evaporator gets icing and eventually suction pressure drops down.

The system is not overcharged as the level of regrigerant in sight glass of condenser is just below half.

Do we need to starve the evaporator by adjusting TEX?? for that we need to turn adjusting knob on TEX clockwise to increase the superheat right??

Kindly advise.. thank you

Ответить